WARNING • Eyebrow LCD: no FL

Dometic & Norcold Refrigerators: Norcold 'no FL' — No Flame on LP Gas

Burner failed to ignite or thermocouple failed to sense flame after 3 ignition cycles.

← Live Decoder
Field Safety Warning: Shut off the LP tank valve and wait 5 minutes before working inside the burner box.

Checkable Field Troubleshooting Steps

Most Probable Root Causes

  • Empty LP tank, closed valve, or air in propane line
  • Spider web in the burner orifice/venturi tube
  • Misaligned spark electrode (gap should be 1/8–3/16 in) or bad lower board
Deep-Dive Technical Guide
RV Fridge Cooling Guide

Understand ammonia-hydrogen absorption physics, test Dometic/Norcold thermistors with an ice-water cup, diagnose 'no co' and 'no FL' lockouts, and spot cooling-unit fire hazards.

Read Complete Field Guide →

OEM Replacement Parts & Cross-References

Norcold OEM: 628661
Norcold N6/N8/1200 Power Circuit Board
Cross-Ref: Dinosaur N628661

Fixes dead eyebrow display and 'no FL' / 'no AC' relay failures.

Disclosure: As an Amazon Associate and eBay Partner, CodeMyRV earns from qualifying purchases at no additional cost to you. See our Affiliate Disclosure.

Frequently Asked Questions About Fridge (Dometic/Norcold) no-fl

What does Fridge (Dometic/Norcold) fault no-fl mean?

Burner failed to ignite or thermocouple failed to sense flame after 3 ignition cycles.

What are the most common causes of Fridge (Dometic/Norcold) no-fl?

Empty LP tank, closed valve, or air in propane line; Spider web in the burner orifice/venturi tube; Misaligned spark electrode (gap should be 1/8–3/16 in) or bad lower board.

What safety precautions apply before troubleshooting no-fl?

Shut off the LP tank valve and wait 5 minutes before working inside the burner box. Always disconnect 120V shore power and shut off LP gas supply valves before probing live electrical or gas components.