WARNING • Wall Panel: E1

Suburban, Atwood & Furrion Thermal: Furrion / Tankless E1 — Ignition Failure

Tankless water heater attempted ignition when hot water flowed but failed to establish flame.

← Live Decoder
Field Safety Warning: Never cover the exterior exhaust grille while operating a tankless water heater.

Checkable Field Troubleshooting Steps

Most Probable Root Causes

  • Propane tank closed or air trapped in LP line
  • Low water flow rate (< 0.65 GPM) failing to trigger flow sensor
  • Low battery voltage (< 10.5V DC) preventing gas valve pull-in
Deep-Dive Technical Guide
RV Furnace & Sail Switch Guide

Trace the exact 12V ignition sequence of Suburban SF/NT and Atwood furnaces: battery voltage thresholds, sail switch lint failures, high-limit switches, and 3-try ignition lockouts.

Read Complete Field Guide →

OEM Replacement Parts & Cross-References

Furrion OEM: C-FWH09EA-010
Furrion Tankless Water Heater Flow Sensor Assembly
Cross-Ref: 2021123859

Fixes E1/E3 flame-out or failure to detect hot water faucet demand.

Disclosure: As an Amazon Associate and eBay Partner, CodeMyRV earns from qualifying purchases at no additional cost to you. See our Affiliate Disclosure.

Frequently Asked Questions About Furnace & Water Heater E1

What does Furnace & Water Heater fault E1 mean?

Tankless water heater attempted ignition when hot water flowed but failed to establish flame.

What are the most common causes of Furnace & Water Heater E1?

Propane tank closed or air trapped in LP line; Low water flow rate (< 0.65 GPM) failing to trigger flow sensor; Low battery voltage (< 10.5V DC) preventing gas valve pull-in.

What safety precautions apply before troubleshooting E1?

Never cover the exterior exhaust grille while operating a tankless water heater. Always disconnect 120V shore power and shut off LP gas supply valves before probing live electrical or gas components.

Other Suburban, Atwood & Furrion Thermal Fault Codes