CRITICAL • 3 Blinks, pause, 6 Blinks

Cummins Onan QG Generators: Code 36 — Engine Stopped Without Command

Most frequent Onan fault: engine died unexpectedly due to fuel, spark, oil level, or air.

← Live Decoder
AMBER (3-6)
2nd-Level Code Retrieval: While the amber switch blinks 3x (Service Fault), press STOP once to read the 2-digit code (3 blinks, pause, 6 blinks).
Field Safety Warning: Keep flames and sparks clear when testing fuel flow from the carburetor inlet line.

Checkable Field Troubleshooting Steps

Most Probable Root Causes

  • Coach fuel tank below 1/4 full (safety pickup tube cutoff)
  • Clogged carburetor jets from ethanol gas sitting > 30 days
  • Failed electric fuel pump (149-2311-02) or fouled spark plug
  • Low oil level tripping the oil level switch
Deep-Dive Technical Guide
Onan Code 36 Playbook

Step-by-step campground troubleshooting for Onan QG generators that crank without starting or die after 3 seconds—covering 2nd-level blink retrieval, fuel cutoff, slip rings, and carb jets.

Read Complete Field Guide →

OEM Replacement Parts & Cross-References

Cummins Onan OEM: 149-2311-02
Onan QG 4000 Microlite Electric Fuel Pump
Cross-Ref: E11007 / 149-2311

Resolves Code 36 fuel starvation on KY-series 4000W gasoline generators.

Cummins Onan OEM: 146-0785
Onan QG 4000 Carburetor Assembly (KY Spec J-P)
Cross-Ref: 146-0803 / A041D736

Fixes surging, hunting, and Code 36 stalls from varnished jets.

Cummins Onan OEM: 167-0275
Onan QG 4000 / 5500 Spark Plug (Gap 0.025 in)
Cross-Ref: Champion RS17YX

Fouled plugs frequently trigger Code 36 or Code 45 cranking faults.

Cummins Onan OEM: 122-0836
Onan QG 5500 / 7000 Spin-On Oil Filter
Cross-Ref: 140-3116 Kit

Pair with 15W-40 or 10W-30 oil change every 150 hours to prevent Code 2/36.

Disclosure: As an Amazon Associate and eBay Partner, CodeMyRV earns from qualifying purchases at no additional cost to you. See our Affiliate Disclosure.

Frequently Asked Questions About Onan Generator 36

What does Onan Generator fault 36 mean?

Most frequent Onan fault: engine died unexpectedly due to fuel, spark, oil level, or air.

What are the most common causes of Onan Generator 36?

Coach fuel tank below 1/4 full (safety pickup tube cutoff); Clogged carburetor jets from ethanol gas sitting > 30 days; Failed electric fuel pump (149-2311-02) or fouled spark plug; Low oil level tripping the oil level switch.

What safety precautions apply before troubleshooting 36?

Keep flames and sparks clear when testing fuel flow from the carburetor inlet line. Always disconnect 120V shore power and shut off LP gas supply valves before probing live electrical or gas components.

Other Cummins Onan QG Generators Fault Codes